Jun,29

API SPEC 5CT-2016 pdf download

API SPEC 5CT-2016 pdf download

API SPEC 5CT-2016 pdf download.Specification for Casing and Tubing.
Page 63, Section 10.15.12 b), revise 1 st sentence to read: Coupling stock containing imperfections may be given further evaluation in accordance with 10.15.15, except the maximum size of the non-surface-breaking imperfection specified in 8.13.1 d) shall be reduced to 32 mm 2 (0.05 in 2 ). Page 63, Section 10.15.12 c), 2 nd sentence, revise to read: The reference indicator shall be a 6,4 mm (1/4 in) flat bottomed round hole from the inside surface as shown in Figure D.16 d. Page 64, Section 10.15.16, 2 nd paragraph, 1 st sentence, revise to read: When no imperfection is found in the area of the original indication and there is no explanation for the indication, then the product shall be rejected or, at the manufacturer’s option, re-inspected full-body, full-length either using the same inspection method or using ultrasonic inspection methods. Page 67, Section 11.1.9, revise to read: Products manufactured in accordance with this edition of API 5CT during the period of overlap of application with the previous edition shall be identified by using either “0” as the overlap period designation rather than the quarter, or “00” as the overlap period designation rather than the month. The overlap period designation “0” or “00” applies to the pipe body characteristics and does not apply to changes in API Spec 5B. Page 67, Section 11.2.4, revise Title to read: Group 1 (except Grade R95) and Group 3 Page 68, Section 11.4.2, 1 st paragraph, revise to read: The following methods shall be used, as applicable. Page 76, Section A.6.5.1, delete section and renumber subsequent sections. Page 78, Section A.7.3, 1 st paragraph, 2 nd and 3 rd sentences, revise to read: If an impact test specimen fails to conform to the specified requirements, the manufacturer shall follow the re-test provisions of 10.7.8, 10.7.9 and 10.7.10 (as applicable). If a hardness test specimen fails to conform to the specified requirements, the manufacturer shall follow the re-test provisions of 10.6.14 to 10.6.19 (as applicable).
Page 82, Section A.10.2.5, 1 st sentence, revise to read: At the manufacturer’s option, alternative-size impact test specimens, listed in Table C.55 (SR16.3) or Table E.55 (SR16.3), may be used in lieu of the minimum size specified in the tables referenced in A.10.2.2 (SR16.2.2). Page 84, Section A.10.6.3, 3 rd paragraph, revise to read: The test temperature shall be reduced as specified in A.10.6.5 SR16.6.5 for Grades H40, J55 and K55 when subsize test specimens are required. Page 85, Section A.10.6.7, last sentence, revise to read: The impact energy of each of the re-test specimens shall equal or exceed the specified minimum absorbed energy requirement or the product shall be rejected. Page 85, Section A.10.6.8, 2 nd sentence, revise to read: If all the additional products tested conform to the requirements, then the lot shall be qualified except for the product that was initially rejected. Page 88, Section A.13.1, 1 st sentence, revise to read: For each lot, as defined in 10.2, manufacturers shall carry out an ANSI-NACE TM0177:2005 Method D test with the test solution specified in A.13.3 SR39.3. Page 91, Section B.2, 1 st and 2 nd sentences, revise to read: The inspector representing the purchaser shall have unrestricted access, at all times while work on the contract of the purchaser is being performed, to all parts of the manufacturer’s works which will concern the manufacturer of the products ordered. The manufacturer shall afford the inspector all reasonable facilities to satisfy the inspector that the product is being manufactured in accordance with this Standard.
Page 223, Section F.4.1.2, revise 1 st sentence to read: For all manufacturers except threaders, the marking instructions in this annex, except those in F.4.6, are applicable. Page 223, Section F.4.1.9, revise to read: Products manufactured in accordance with this edition of API 5CT during the period of overlap of application with the previous edition shall be identified by using either “0” as the overlap period designation rather than the quarter, or “00” as the overlap period designation rather than the month. The overlap period designation “0” or “00” applies to the pipe body characteristics and does not apply to changes in API Spec 5B. Page 224, Section F.4.2.1, 2 nd paragraph revise 1 st sentence to read: After stamp marking, group 2 and group 4 products can require subsequent heat treatment as specified in F.4.2.5. Page 224, Section F.4.2.4, revise to read: When specified on the purchase agreement, products shall be stamped by one or more of the methods in F.4.2.1 at the option of the manufacturer.

Download
The previous

API SPEC 10A-2019 pdf download

The next

API SPEC 4F-2020 pdf download

Related Standards